Pioneers in the industry, we offer self priming pump (shree ram red self priming pump 1.00 hp big flow), self priming pump (shree ram red self priming pump 0.50 hp big flow), self priming pump (shree ram red self priming pump 0.50 hp sharp type eco), self priming pump (shree ram red self priming pump 1.00 hp sharp type eco), self priming pump (shree ram red self priming pump 0.50 hp sharp type) and self priming pump (shree ram red self priming pump 1.25 hp big flow) from India.
₹ 4593 / Piece Get Latest Price
| Power Rating | 0.75 kW (1 HP) |
| Power | 1 HP |
| Suction Size | 25 mm (1 inch) |
| Pump Material | Aluminium |
| Maximum Head | up to 50 m |
| Discharge Range | 40–100 LPM |
| Pipe Size | 25 mm X 25 mm (1") |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Speed | 3000 rpm |
| Voltage | 220–240 V |
| Country of Origin | Made in India |
| Flow Rate | up to 9000–11000 LPH |
| Usage/Application | Domestic & commercial |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 4258 / Piece Get Latest Price
| Power | 0.5 HP, 0.5 HP |
| Power Rating | 0.37 kW (0.5 HP) |
| Suction Size | 25 mm (1 inch) |
| Pump Material | Aluminium |
| Maximum Head | 25 m |
| Flow Rate | up to 6600 LPH |
| Discharge Range | 7 to 25 LPM |
| Pipe Size | 25 mm X 25 mm (1") |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Usage | Domestic |
| Impeller Material | Brass |
| Power Source | Electric |
| Voltage | 220–240 V |
| Speed (RPM) | 2880 RPM |
| Warranty | 12 Months |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 2717 / Piece Get Latest Price
| Power | 0.5 HP |
| Power Rating | 0.37 kW (0.5 HP) |
| Pump Material | Aluminium |
| Suction Size | 25 mm (1 inch) |
| Maximum Head | Up to 50 mtrs |
| Pipe Size | 25 mm X 25 mm (1") |
| Discharge Range | 7–20 LPM |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Power Source | Electric |
| Speed | 3000 rpm |
| Speed (RPM) | 2880 RPM |
| Voltage | 220–240 V |
| Country of Origin | Made in India |
| Flow Rate | up to 6600 LPH |
| Usage/Application | Home, small tank filling |
| Pipe Size / Discharge Outlet Size | 15x15 mm to 25x25 mm |
| Material Type | Aluminium Body |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 3186 / Piece Get Latest Price
| Power Rating | 0.75 kW (1 HP) |
| Power | 1 HP |
| Suction Size | 25 mm (1 inch) |
| Pump Material | Aluminium |
| Maximum Head | Up to 50 mtrs |
| Flow Rate | up to 7500–8500 LPH |
| Discharge Range | 10–30 LPM |
| Pipe Size | 15–25 mm |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Speed | 3000 rpm |
| Power Source | Electric |
| Voltage | 220–240 V |
| Warranty | 12 Months |
| Country of Origin | Made in India |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 3454 / Piece Get Latest Price
| Power Rating | 0.37 kW (0.5 HP) |
| Motor Power | 0.5 HP, 0.5 HP |
| Suction Size | 25 mm (1 inch) |
| Pump Material | Aluminium |
| Maximum Head | Up to 50 mtrs |
| Flow Rate | Up to 6600 LPH |
| Discharge Range | 15–40 LPM |
| Pipe Size | 25 mm X 25 mm (1") |
| Max Flow Rate | up to 6000–7000 LPH |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Power Source | Electric |
| Speed | 3000 rpm |
| Voltage | 220–240 V |
| Speed (RPM) | 2880 RPM |
| Use | Household water supply |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 5129 / Piece Get Latest Price
| Power | 1.25 HP |
| Power Rating | 1.25 HP |
| Pump Material | Aluminium |
| Suction Size | 25 mm (1 inch) |
| Maximum Head | up to 50 m |
| Flow Rate | up to 12000+ LPH |
| Pipe Size | 25 mm X 25 mm (1") |
| Discharge Range | 50–110 LPM |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Speed | 3000 rpm |
| Power Source | Electric |
| Voltage | 220–240 V |
| Country of Origin | Made in India |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
₹ 4459 / Piece Get Latest Price
| Power Rating | 0.75 kW (1 HP) |
| Power | 1 HP |
| Suction Size | 25 mm (1 inch) |
| Pump Material | Aluminium |
| Maximum Head | Up to 50 mtrs |
| Discharge Range | 20–50 LPM |
| Pipe Size | 25 mm X 25 mm (1") |
| Max Flow Rate | up to 8000–9500 LPH |
| Suction Lift | 6–8 m |
| Phase | Single Phase |
| Impeller Material | Brass |
| Speed | 2800 rpm |
| Power Source | Electric |
| Voltage | 220–240 V |
| Speed (RPM) | 2880 RPM |
| Country of Origin | Made in India |
| Flow Rate | up to 8000–9500 LPH |
| Usage/Application | Domestic use |
| Pipe Size / Discharge Outlet Size | 15x15 mm to 25x25 mm |
| Material Type | Aluminium Body |
Minimum order quantity: 5 Piece
Pumps that are partially or completely above the fluid level allow air into the suction line, which must be evacuated or displaced before the pump can move the liquid. Self-priming pumps are capable of removing air at startup before beginning its normal pumping functions.
To avoid the mixing of air and water, self-priming pumps create a partial vacuum to discharge water while also evacuating any air. It does this by combining the air and water during the priming process, forcing the air to rise and the water to sink or go down. Gravity then pulls the air-free water back into the impeller, where it mixes with the remaining air in the suction line.
This process repeats until all air is evacuated and a vacuum forms in the suction line. Once this happens, atmospheric pressure forces the water into the suction line and towards the impeller to allow pumping to begin.
Application :
Ashwin Ghedia (CEO)
Shree Ram Pump & Pipe
Opp. Bank Of Baroda, Dhebar Road
Rajkot Municipal Corporation, Rajkot - 360001, Gujarat, India